Changzhou Skyerscale Co.,Limited

Changzhou Skyerscale Co., Limited Changzhou JRBao Electronic Manufacturing Co.,Ltd.

Manufacturer from China
Verified Supplier
9 Years
Home / Products / Weighing Load Cell /

Hermetically Sealed Double Ended Beam Load Cell

Contact Now
Changzhou Skyerscale Co.,Limited
Visit Website
City:changzhou
Province/State:jiangsu
Country/Region:china
Contact Person:MsFang
Contact Now

Hermetically Sealed Double Ended Beam Load Cell

Ask Latest Price
Video Channel
Brand Name :OEM
Model Number :DLC101
Certification :CE
Place of Origin :China
MOQ :1pcs
Price :negotiation
Supply Ability :100pcs/m
Delivery Time :25days
Packaging Details :carton
Material :Alloy steel ,stainless steel
Theory :Resistance Sensor
Output :digital Sensor
Usage :Pressure Sensor
sealing class :IP67-IP68
name :beam type load cell
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Double ended shear beam load cell onboard truck scale,axle load sensor 1klb~75klb

Specifications:

Hermetically Sealed Double Ended Beam Load Cell

Cap/Size A B C D E F H
1~5KLB 190.5 158.8 31 31 29 31.5 13
10~25KLB 222.3 190.5 49.3 36.5 42 50.5 20.6
35KLB 222.3 190.5 63.5 38 50 63 20.6
50~75KLB 343 292 75 62 83 76.2 33.3

Dimensions:Unit: mm

Rated Load: 1~75klb Insulation Resistance: ≥5000MΩ
Rated Output: 1000000 Operating Temp. Range: -30~+70℃
Baud Rate:: 9600 Baud Maximum Safe Over Load: 150%F.S
Measuring Rate: 80/sec Ultimate Over Load: 250%F.S
Communication Mode: RS485/4-wire Recommend Excitation Vol.: 10~12V DC
Combined Error: ±0.03% F.S Maximum Excitation Vol.: 15V DC
Creep Error(30min): ±0.02% F.S Sealing Class: IP67/IP68
Zero Balance: ±1% F.S Element Material: Alloy /Stainless Steel
Temp. Effect On Zero: ±0.017% F.S/10℃ Cable: Length=13m
Temp. Effect On Span: ±0.017% F.S/10℃ Citation: GB/T7551-2008/ OIML R60
Mode Of Connection: Red(Input+),Black(Input-),Green(Output+),White(Output-)

Description:

Double Ended Beam Load Cells LC106D is a reliable sealing and mechanical protection of the strain gauge area is ensured by the use of potting compound with a metal cover. LC106D digital load cell. Digital output signal (RS-485/4-Wire). Normal load 1~75 Klb. Self-restoring rocker pin. Easy to install. Hermetically sealed. Produce according OIML R60 to 3000d. Over voltage protection.

Applications:

Weighing functions

Competitive Advantage:
1. Professional manufacturer with 10 years

2. OEM/ODM service acceptable

3. 100% inspection

4. Warranty: one year