Changzhou Skyerscale Co.,Limited

Changzhou Skyerscale Co., Limited Changzhou JRBao Electronic Manufacturing Co.,Ltd.

Manufacturer from China
Verified Supplier
9 Years
Home / Products / Digital Weight Indicator /

High Precision Digital Scale Indicator With LED Display

Contact Now
Changzhou Skyerscale Co.,Limited
Visit Website
City:changzhou
Province/State:jiangsu
Country/Region:china
Contact Person:MsFang
Contact Now

High Precision Digital Scale Indicator With LED Display

Ask Latest Price
Video Channel
Brand Name :CAISUN
Model Number :XK315A2-6
Place of Origin :China
MOQ :1
Price :negotiation
Supply Ability :500pcs/M
Delivery Time :7~10days
Packaging Details :carton
A/D Converter type :Sigma-Delta
Display Type :LED
Signal output :4-20 mA analog output
Display resolution :3000
Power Supply :DC 9V 1A adapter or AC 110-220V 50 Hz
Load cell excitation :DC 5V
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

High Precision control indicator A2-6 Series Weighing Controller (4~20MA)

Specification

A/D Converter type Sigma-Delta
Sample rate 10 times / second (50 times / second optional)
Display resolution 3000
Internal resolution 1,000,000
Load cell excitation DC 5V
Load cell Up to 4 x 350 Ω or 8 x 700 Ω load cell
Display 6-digit 0.4 inch LED
Division

1/2/5/0.1/0.2/0.5/0.01/0.02/0.05/0.001/0.002/0.005/10/

20/50/100/200/500/0.10/0.20/0.50/0.010/0.020/0.050

Power DC 9V 1A adapter or AC 110-220V 50 Hz
Operating temperature 0℃~40℃
Storage temperature -25℃~55℃
Relative humidity 85% RH
Size 95 × 48 × 110 mm
Weight 0.5 kg
Signal output 4-20 mA analog output
Options

a) Opto-isolated RS232 or RS485

b) 6 relay outputs with 2 opto-isolated inputs that can be used to control the output of relay #1 and #2

1. Model Number

XK315A2-6□-□□-□

0 - No interface

1 - Optical -isolated RS232C

2 - Optical -isolated RS485

AC - AC 110-220V 50 Hz available for XK315A2-6A series only

DC - DC 9V 1A adapter

A - Basic model with 4-20 mA analog output

B - Basic model plus 6 relay outputs and 2 opto-isolated inputs

2. Key Functions

* 】 Function Select key or Enter key

【→】 Right key

【→T←】 Tare key or Increment key

【→0←】 Zero key or Decrement key

3. Status

〖→T←〗 On when tare and the weight is net weight

〖→0←〗 On when the weight is zero

〖◣◢〗 On when the weight is stable

4. Error Code

〖 OUEr〗 - when the weight is > 100% FS + 9d

〖-OUEr〗 - when the weight is < - 20d

〖HHHHHH〗 - when zero reference is > +2% FS

〖LLLLLL〗 - when zero reference is < -2% FS

5. Interface Operation

Serial format 8-N-1: 8 data bits, No parity bit, 1 stop bit.

1. Adr=00 - continuous ASCII reverse data output, if weight is -123.45, the output is 54.321-

2. Adr=99 - continuous ASCII regular data output, if weight is -123.45, the output is -123.45

3. Adr=01-98 - data output using ModBus protocol

6. Operation

1. Turn on the indicator, it displays the version number and checks the LED from “0” to “9”

2. Zero

· When the weight is stable between ±2% FS,press【→0←】zero the display and〖→0←〗is on

· When the zero reference is > +2% FS, it displays 〖HHHHHH〗

· When the zero reference is < -2% FS, it displays 〖LLLLLL〗

3. Tare

· When the weight is stable,〖→T←〗is on

· When the weight is greater than zero and stable,〖◣◢〗 is on

· Press【→T←】zero display and〖→T←〗is on

4. Clear Tare

· When the weight is stable and the weight is net weight,〖→T←〗is on

· Press【→T←】clears the tare and〖→T←〗is off

7. Configurations

Operation Display Descriptions
Press【→】 〖000000〗 Go to Calibrations and Configurations menu and enter password 002003

Press【→】

Or【→T←】

〖002003〗

To enter password 002003:

· Press【→】to move blinking digit to the right

· Press【→T←】to increment blinking digit

· Press【→0←】to decrement blinking digit

Press【 * 〖CAL SP〗 In Calibrations menu
Press【 * 〖-SEt-〗 In Configurations menu
Press【→】 〖d 0.01〗 Set division
Press【→T←】 〖d 0.05〗 Press【→T←】or【→0←】to select d
Press【 * 〖 100.00〗 Set FS
Press【→】 〖000000〗 Left most digit is blinking

Press【→】

Or【→T←】

〖0300.00〗 Press a combinations of【→】,【→T←】and【→0←】to select FS
Press【 * 〖FLt 2〗

Set filter. FLt=0-2

The bigger filter will result in slower weight result

Press【→T←】 〖FLt 1〗 Press【→T←】or【→0←】to select filter
Press【 * 〖AUtP00〗

Set zero trace range and zero at start range

AUtP=00 no zero set at start,zero trace range is 0.4d;

AUtP=10 zero at start range 20% FS,zero trace range is 0.4d;

AUtP=20 zero at start range 20% FS,zero trace range is 0.8d;

AUtP=30 zero at start range 20% FS,zero trace range is 1.2d;

AUtP=40 zero at start range 20% FS,zero trace range is 1.6d;

AUtP=50 zero at start range 20% FS,zero trace range is 2.0d;

AUtP=60 zero at start range 20% FS,zero trace range is 2.4d;

AUtP=70 zero at start range 20% FS,zero trace range is 2.8d;

AUtP=80 zero at start range 20% FS,zero trace range is 3.2d;

AUtP=90 zero at start range 20% FS,zero trace is 3.6d;

Press【→】

Or【→T←】

〖AUtP10〗 Press a combinations of【→】,【→T←】and【→0←】to select AUtP
Press【 * 〖Adr 00〗

Enter indicator address

Adr=00 continuous reverse data output

Adr=99 continuous regular data output

Adr=01-98 data output using ModBus protocol

Press【→】

Or【→T←】

〖Adr 12〗 Press a combinations of【→】,【→T←】and【→0←】to select Adr
Press【 * 〖b 2400〗

Set Baud rate

b=1200,2400,4800,9600

Press【→T←】 〖b 9600〗 Press【→T←】or【→0←】to select baud rate
Press【 * 〖L00791〗

Calibrate the 4 mA analog output

L means current output is 4 mA

Press【→】

Or【→T←】

〖L00791〗 Press a combinations of【→】,【→T←】and【→0←】to calibrate the 4 mA analog output
Press【 * 〖H03723〗

Calibrate the 20 mA analog output

H means current output is 20 mA

Press【→】

Or【→T←】

〖H03723〗 Press a combinations of【→】,【→T←】and【→0←】to calibrate the 20 mA analog output
Press【 * 〖 0.00〗 Save all parameters

Applications:

Electronic platform scale, weighing scale, etc.

Advantage:

1. High Quality:
We have strict quality control system, all of our products comply with international quality standards and are greatly in a variety of different markets throughtout the world.

2. Outstanding Customer Service
We are a professional manufacturer and exporter committed to weighing equipments research and manufacture.

3. Low MOQ & Fast Delivery:
Small order quantity and flexible payment terms, it can meet your promotional business very well.
Fast delivery, it can meet your urgent needs.

Please contact us:
whatsapp/Tel:0086 15995095496
skyer@skyerscale.com
www.floorweighingscales.com

Inquiry Cart 0